Locker Room & Athletic Equipment

US Restoration Industry (Active) Chlorine Dioxide Standard Protocols:

  • Vaporing for Deodorization: 100 Grams ClO₂ in 32 oz water (with aerator) treats up to 500 ft² with 10′ ceiling
  • Vaporing for Mold Removal: 100 Grams ClO₂ in 32 oz water (with aerator) treats up to 100 ft² with 10′ ceiling
  • Liquid: (M) 100ppm or (H) 500ppm on porous and non-porous surfaces

Proven safe on uniforms, athletic equipment, steel, plastics, vinyl, rubber, upholsteries, wood, marble, electronics and wiring.

Using Reset In the Locker Room & on Athletic Equipment

Eco friendly iconChlorine Dioxide (ClO₂) safely removes and deodorizes pungent organic and chemical based odors from all porous and non-porous surfaces in Locker Room Environments.

Removes bio-fluids, mold and mildew, chemical masking agents, food & garbage odors and anything else you can imagine!

Reset ClO₂ may be generated and used as either a VAPOR or LIQUID.

Reset ClO₂ features: No Rising or Wiping Required, Non-Masking, Non-Staining, Non-Corrosive, No Fragrances, No VOCs, Near Neutral pH, No Enzymes.

STEP 1: Quickly Reset Atmosphere & Targeted Surfaces with ClO₂ Liquid

green liquid pouring

Simply add pre-measured, color coded Reset CLO₂ Tablets to water and ANY UNIVERSAL SIZE opaque container or dispersion tool to generate desired concentration or application requirement.

Apply Reset (M) 100ppm or (H) 500ppm liquid into the atmosphere and onto all porous & non-porous surfaces with a mop, sponge, pump sprayer or non-thermal fogger.

Step 1 is often not required when using Reset Vapor Mold Removal Level.

STEP 2: Reset Environment & Its Contents with ClO₂ Vapor

3 to 24 hours treatment time depending on severity of issue

Create a confined space. Select Reset Usage Level.

Use (M) Deodorization Level to reset to neutral any environment & its contents from wide-spectrum pungent & resistant odors.

Use (H) Mold Removal Level for extreme environment issues. (not contents)

Simply add pre-measured, color coded Reset CLO₂ Tablets to water and either a 32 oz. cup, 1 gallon pail or 5 gallon bucket (with Aerator).

Follow easy to understand product Vapor activation instructions and support videos.

STEP 3: Re-Occupy Space

fitness studio with gym equipment

Air-out CLO₂ from the confined space before re-occupying if using the Vapor protocol.

Pour residual Vapor concentrate down toilet or drain.